Optional Equipment (for qualified installers only) | 65 |
4 Install the strain relief plate to the firebox floor following the directions below
aInsert the four wires through the strain relief plate (NOTE: Put the
larger, male connectors through first).
bSecure the wires using the included strain relief (wrap the strain relief over the wires, compress
with pliers, then insert into the hole).
=
d
Route the wires behind the pilot
assembly. There are two small tabs on the pilot bracket that can be bent down to secure the wiring. All wiring must be secured away from the burner.
c
Secure the strain relief plate to the firebox floor with the screws removed earlier.
5Restore the firebox to the correct configuration (replace the burner, firebacks, logs).
If using the optional
6Install the rheostat assembly following the directions below.
Attach the
the accent light assemblies (orientation does not matter). Plug the rheostat into the receptacle.
a | Attach the rheostat assembly to the | |
fireplace with the included screws. | ||
|
© Travis Industries | 4070201 |