Optional Equipment (for qualified installers only)

65

4 Install the strain relief plate to the firebox floor following the directions below

aInsert the four wires through the strain relief plate (NOTE: Put the

larger, male connectors through first).

bSecure the wires using the included strain relief (wrap the strain relief over the wires, compress

with pliers, then insert into the hole).

=

d

Route the wires behind the pilot

assembly. There are two small tabs on the pilot bracket that can be bent down to secure the wiring. All wiring must be secured away from the burner.

c

Secure the strain relief plate to the firebox floor with the screws removed earlier.

5Restore the firebox to the correct configuration (replace the burner, firebacks, logs).

If using the optional wall-mounted rheostat, follow the directions on the following page "Wall Mounted Rheostat".

6Install the rheostat assembly following the directions below.

Attach the quick-connects from the b rheostat to the quick-connects from

the accent light assemblies (orientation does not matter). Plug the rheostat into the receptacle.

a

Attach the rheostat assembly to the

fireplace with the included screws.

 

© Travis Industries

4070201

100-01182_002

Page 65
Image 65
North Star 864 HH installation manual Optional Equipment for qualified installers only