3.2.7 Alarm 1 Menu

This unit is equipped with two physical outputs that can only be configured as follows: Alarm 1 & Alarm 2, Alarm 1 & Output 2, Output 1 & Alarm 2, Output 1

&Output 2, Analog Out 1 & Alarm 2, Analog Out 1 & Output 2. Analog Out available only if Analog Output Option board is factory installed.

If Analog Output Option is installed, the controller will skip Alarm 1 Menu item to Analog Output.

Alarm must be DISABLED if Ramp is ENABLED.

Figure 3.5 Flow Chart for Alarm 1 Menu

ENTER ALARM 1 MENU:

Press a 1) Press a, if necessary, until CNFG prompt appears. Press d 2) Display advances to INPT Input Menu.

Press a 3) Press a, if necessary, until Display advances to ALR1 Alarm 1 Menu.

Press d 4) Display advances to Alarm 1 ENBL Enable or DSBL Disable Submenu and flashes the previous selection.

26

Page 30
Image 30
Omega CNiS8DH, CNiS32, CNiS16D, CNiS8DV, CNiS8C manual Enter Alarm 1 Menu