Omega Vehicle Security FPU5-MT-110, FPU5-MT-220 manual Problem, Solution, Motor will not turn

Models: FPU5-MT-110 FPU5-MT-220

1 83
Download 83 pages 6.26 Kb
Page 69
Image 69
Manual background

7Troubleshooting Guide

Problem

 

Solution

 

Motor will not turn

1.

The tubing may be causing a jam. Observe how the tubing is loaded

(OVERCURRENT condition)

 

in the pump(s) and, if necessary, reload it.

 

2.

Detach the pump(s) and check for a mechanical jam. Substitute

To recover from an

 

another pump, if necessary.

3.

Check to see if the fuse is blown. Replace if necessary. Refer to

overcurrent, first turn

the power switch off,

 

Chapter 9 for fuse ratings and chapter 8 for instructions on how to

and then back on.

 

replace it.

Then attempt solutions

 

 

 

 

1 through 8.

4.

Make sure you are using tubing of the appropriate wall thickness for

 

 

the pump(s). Refer to Table 9-1 or 9-2.

 

5.

Make sure you are using tubing of the appropriate durometer for

 

 

your pump(s). Try to operate the motor with tubing of 68 or smaller

 

 

durometer.

 

6.

Make sure the tubing is not caught on the bottom roller. Reposition

 

 

the roller slightly and reload the tubing, if necessary.

 

7.

Make sure no part of the tubing is being constricted by a clamp.

 

 

Loosen clamps if necessary.

 

8.

Turn the unit’s power off and on, adjust the settings, and attempt to

 

 

resume pumping.

 

 

 

 

The pump(s) will not stay on

1.

Make sure you have properly mounted the pump(s) to the motor.

the motor

 

2.

If the pump(s) are not properly mounted, review Section 3.1 on how

 

 

to attach pump(s) to the motor.

 

3.

Remove and properly attach the pump(s) to the motor.

 

 

 

 

Pump messages appear in a language other than the one you want

The LANGUAGE button was inadvertently pressed. Make sure that you are pumping in a mode other than the TIME Mode before pressing the LANGUAGE button, so you can watch the language change. To change languages, refer to Section 5.1.

Problem has not been resolved

Call Customer Service

following the suggestions in

 

this chapter

 

 

 

7-10

Page 69
Image 69
Omega Vehicle Security FPU5-MT-110, FPU5-MT-220 manual Problem, Solution, Motor will not turn