Panasonic AW-E560 manual GEN-LOCK Adjustment, Horizontal Phase Control

Models: AW-E560

1 63
Download 63 pages 62.37 Kb
Page 31
Image 31

GEN-LOCK ADJUSTMENT

Phase adjustments must be performed with the camera or the RCU (RCB) when external synchronizing signals are supplied to the system in cases where multiple cameras are used or peripheral devices are connected.

ENC

OFF

 

 

 

 

PAGE

ITEM

UP

DOWN

VF

ON

 

SC PHASE

 

 

 

USER SET

 

COARSE

FINE

H.PHASE

0

270

 

 

 

 

 

 

90

180

 

Horizontal phase

 

 

 

Subcarrier phase

control

 

 

 

fine control

Subcarrier phase coarse control

HORIZONTAL PHASE CONTROL

Observe the waveform of the external synchronizing input signal (black burst signal) and video output signal on a two-channel oscilloscope. Then match the horizontal phase of both signals by adjusting them with the cameras or RCU's horizontal phase control.

External gen-lock input signal (black burst output of special effect generator)

Video signal

[ADJUSTMENT by CAMERA]

1.Press the BAR (DOWN) switch for over 1 second to display the color bar.

2.Select page No.4 of INITIAL SET menu.

3.Select “H PHASE” with the item switch.

4.Adjust the horizontal phase with the Up switch and Down switch.

NO.4 ** INITIAL **

H PHASE

+

....

I....

-

 

SC COARSE

 

 

 

SC FINE

+

....

I....

-

RET END

[ADJUSTMENT WITH RCU (RCB)]

Use the horizontal phase control located in the pocket of RCU (RCB).

-29-