Panasonic AW-E560 manual Reset to 3200K or 5600K White Balance, Adjustment with RCU or RCB

Models: AW-E560

1 63
Download 63 pages 62.37 Kb
Page 30
Image 30

RESET TO 3200K OR 5600K WHITE BALANCE

When the white balance setting is set to either “P SET 3.2K” or “P SET 5.6K” the white balance will be automati- cally set to the color temperature 3,200K or 5,600K respectively.

BLACK BALANCE ADJUSTMENT [ADJUSTMENT by CAMERA]

Press the ABC (UP) Switch for over 1 second and the black balances for 0dB, 9dB and 18dB will be automatical- ly set in 5 seconds.

If the painting switch is ON in the page No.1 of INITIAL SET menu, black balance fine adjustment can be per- formed with the red gain/blue gain control.

[ADJUSTMENT WITH RCU OR RCB]

Set the auto white/auto black set switch to ABC and the black balance will be automatically set regardless of cam- era mode. While the system is being set, the auto warning indicator (LED) blinks and it goes out when the black bal- ance setting is completed. If the lamp remains lit, ABC should be tried again.

TOTAL PEDESTAL LEVEL ADJUSTMENT

(Use an oscilloscope or a waveform monitor for this adjust- ment.)

[ADJUSTMENT by CAMERA]

1.Select the page No.1 of the INITIAL SET menu on the monitor screen.

2.Select “T PED” with the item switch.

-28-

3.Set the pedestal level to 7.5IRE (0.050V) with the Up switch and the Down switch.

NO.1 ** INITIAL **

R GAIN

+

....

I....

-

B GAIN

+

....

I....

-

T PED

+

....

I....

R PED

+

 

....

-

....

I

B PED

+

....

I....

-

PAINTING

 

OFF

 

RET END

 

 

 

 

[ADJUSTMENT WITH RCU (RCB)]

Adjust the total pedestal level to 7.5IRE with the total pedestal adjustment.

Minimize the carrier wave using the red & blue gain controls

7.5 IRE

(0.050V)

Page 30
Image 30
Panasonic AW-E560 manual Reset to 3200K or 5600K White Balance, Black Balance Adjustment Adjustment by Camera