RESET TO 3200K OR 5600K WHITE BALANCE

When the white balance setting is set to either “P SET 3.2K” or “P SET 5.6K” the white balance will be automati- cally set to the color temperature 3,200K or 5,600K respectively.

BLACK BALANCE ADJUSTMENT [ADJUSTMENT by CAMERA]

Press the ABC (UP) Switch for over 1 second and the black balances for 0dB, 9dB and 18dB will be automatical- ly set in 5 seconds.

If the painting switch is ON in the page No.1 of INITIAL SET menu, black balance fine adjustment can be per- formed with the red gain/blue gain control.

[ADJUSTMENT WITH RCU OR RCB]

Set the auto white/auto black set switch to ABC and the black balance will be automatically set regardless of cam- era mode. While the system is being set, the auto warning indicator (LED) blinks and it goes out when the black bal- ance setting is completed. If the lamp remains lit, ABC should be tried again.

TOTAL PEDESTAL LEVEL ADJUSTMENT

(Use an oscilloscope or a waveform monitor for this adjust- ment.)

[ADJUSTMENT by CAMERA]

1.Select the page No.1 of the INITIAL SET menu on the monitor screen.

2.Select “T PED” with the item switch.

-28-

3.Set the pedestal level to 7.5IRE (0.050V) with the Up switch and the Down switch.

NO.1 ** INITIAL **

R GAIN

+

....

I....

-

B GAIN

+

....

I....

-

T PED

+

....

I....

R PED

+

 

....

-

....

I

B PED

+

....

I....

-

PAINTING

 

OFF

 

RET END

 

 

 

 

[ADJUSTMENT WITH RCU (RCB)]

Adjust the total pedestal level to 7.5IRE with the total pedestal adjustment.

Minimize the carrier wave using the red & blue gain controls

7.5 IRE

(0.050V)

Page 30
Image 30
Panasonic AW-E560 manual Reset to 3200K or 5600K White Balance, Black Balance Adjustment Adjustment by Camera