Description Specifies the time (hour:minute) that the unit checks for updates of
configuration files.
Value Range 00:00–23:59
Note
If the value for this setting is any valid value other than an empty
string, the unit downloads the configuration files at the fixed
time, and the settings specified in "CFG_CYCLIC",
"CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" are
disabled.
If the value for this setting is an empty string, downloading the
configuration files at the fixed time are disabled.
Default Value Empty string
CFG_RESYNC_FROM_SIP
Value Format String
Description Specifies the value of the "Event" header sent from the SIP server to
the unit so that the unit can access the configuration files on the
provisioning server.
Value Range Max. 15 characters
Note
An empty string is not allowed.
Default Value check-sync
Web User Interface Reference Header Value for Resync Event (Page 176)
USR_PROV_SVR_URL
Value Format String
Description Specifies the Provisioning Server URL.
Note
The format of the IP address must be in dotted-decimal
notation, FQDN, or URL, as follows:
"<scheme>://<user>:<password>@<host>:<port>/<url-path>"
If "{mac}" is included in this URL, it will be replaced with the
unit’s MAC address in lower-case.
If "{MAC}" is included in this URL, it will be replaced with the
unit’s MAC address in upper-case.
If "{MODEL}" is included in this URL, it will be replaced with the
unit’s model name.
If "{fwver}" is included in this URL, it will be replaced with the
unit’s firmware version.
Value Range Max. 1024 characters
236 Administrator Guide Document Version 2014-05
5.3.6 Provisioning Settings