Description Specifies the dual-tone frequencies, in hertz, of the hold alarm using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 425
HOLD_ALARM_GAIN
Value Format Integer
Description Specifies the gain, in decibels, of the hold alarm.
Value Range (-80)–0
Default Value 0
HOLD_ALARM_RPT
Value Format Boolean
Description Specifies whether the hold alarm is repeated.
Value Range Y (Repeat)
N (No Repeat)
Default Value Y
HOLD_ALARM_TIMING
Value Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of the hold alarm using up to 10
whole numbers (on 1, off 1, on 2, off 2…) separated by commas.
Value Range 0–16000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 120,14880
CW_TONE1_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of call waiting tone 1 using
2 whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 425
272 Administrator Guide Document Version 2014-05