REORDER_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of reorder tones using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 480,620
Web User Interface Reference Tone Frequencies (Page 150)
REORDER_TONE_GAINValue Format Integer
Description Specifies the gain, in decibels, of the reorder tone.
Value Range (-80)–0
Default Value 0
REORDER_TONE_RPTValue Format Boolean
Description Specifies whether the reorder tone is repeated.
Value Range •Y (Repeat)
•N (No Repeat)
Default Value Y
REORDER_TONE_TIMINGValue Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of reorder tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Infinite time)
Note
•Avoid setting 1–50 for any of the values.
Default Value 60,250,190
Web User Interface Reference Tone Timings (Page 150)
270 Administrator Guide Document Version 2014-05
5.5.6 Tone Settings