Description Specifies the dual-tone frequencies, in hertz, of Dial Tone 1 using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 350,440
Web User Interface Reference Tone Frequencies (Page 147)
DIAL_TONE1_GAINValue Format Integer
Description Specifies the gain, in decibels, of Dial Tone 1.
Value Range (-80)–0
Default Value 0
DIAL_TONE1_RPTValue Format Boolean
Description Specifies whether Dial Tone 1 is repeated.
Value Range •Y (Repeat)
•N (No Repeat)
Default Value N
DIAL_TONE1_TIMINGValue Format Comma-separated Integer
Description Specifies the pattern, in milliseconds, of Dial Tone 1 using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range 0–16000 (0: Infinite time)
Note
•Avoid setting 1–50 for any of the values.
Default Value 60,0
Web User Interface Reference Tone Timings (Page 148)
DIAL_TONE2_FRQValue Format Comma-separated Integer
Document Version 2014-05 Administrator Guide 265
5.5.6 Tone Settings