10)Press ▲▼ to select [CALIBRATION
TIME].
11)Press the <ENTER> button.
12)Enter the time and press the <ENTER>
button
zzMeasure brightness at a specified time. Dynamic iris is fixed to open during measurement.
13)Press ▲▼ to select [CALIBRATION
MESSAGE].
14)Press ◀▶ to switch [CALIBRATION
MESSAGE].
zzThe setting will change as follows each time you press the button.
[ON] |
|
| [OFF] | |
|
| |||
[ON] | Displays a message during | |||
calibration. | ||||
| ||||
[OFF] | Does not display a message during | |||
calibration. | ||||
|
15) Press ▲▼ to select [APPLY].
16) Press the <ENTER> button.
zzThe set [MODE] and [LINK] are enabled, and LAMP RELAY screen alert is displayed when the [LAMP RELAY] setting is [OFF]. When [CALIBRATION MESSAGE] is set to [ON], a calibration running message is displayed which will automatically disappear 30 seconds after calibration completes.
zzIf the [MODE] in [BRIGHTNESS CONTROL SETUP] is not [OFF] when the <ENTER> button is pressed, the lamp brightness at that time is recorded as the standard brightness.
zzIf the <ENTER> button is pressed when [LINK] is [GROUP A] to [GROUP D], the group name is displayed on the projector screen set as the same group.
/,1.*5283$
Note
zzWhen setting the [MODE] in [BRIGHTNESS CONTROL SETUP] to [AUTO] or [PC], [APPLY] luminance control after the shutter is open for at least two minutes.
zzIf the shutter is closed within approx. 10 minutes from the time that the lamp turns on when operating with the [MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], brightness may be corrected approx. two minutes after the shutter opens because brightness could not be measured.
zzWhen operating with the [MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO] or [PC], lamp brightness is automatically measured eight minutes after a lamp is turned on, and corrected to the same value as the screen brightness and the standard
[PROJECTOR SETUP] menu
brightness at the time of [APPLY]. Lamp brightness cannot be measured during the eight minutes after it is turned on because it is not steady.
zzWhen [LAMP SELECT] is 2 lit or higher and the [MODE] in [BRIGHTNESS CONTROL SETUP] is operating in [AUTO] and a light fails to turn on or LAMP RELAY is performed, brightness is corrected one minute later whenever possible.
zzWhen operating with [MODE] in [BRIGHTNESS CONTROL SETUP] set to [AUTO], and [LINK] is [OFF], brightness correction is performed until correction exceeds the maximum correction amount.
zzIn certain projector environments, dust may accumulate on the lens or screen or inside the projector and increase variation in brightness.
zzAdjust luminance control again when lamp degradation causes increased variation in brightness or a lamp is replaced.
zzFor continued use longer than 24 hours, set the [BRIGHTNESS CONTROL SETUP] to [CALIBRATION TIME], or set [LAMP RELAY] ( page 101). Correction is not automatically executed when not set.
zzLuminance control and iris operate simultaneously, but the iris does not operate when fully open while a brightness measurement is performed.
zzThe setting of [CALIBRATION TIME] applies at the time when the time is entered.
zzThe setting of [CALIBRATION MESSAGE] applies at the time when the item is switched with ◀▶ .
Settings
ENGLISH - 103