Lamp/Temperature/Filter Indicators■■Temperature indicator<TEMP>

Indicator

Lighting in red

Flashing in red

Flashing in red

status

(2 times)

(3 times)

 

 

 

 

Internal

 

 

Status

Warm-up status

temperature

Internal temperature is high

The cooling fan has

is high.

(standby mode)

stopped.

 

 

 

 

(WARNING)

 

 

 

zzDid you turn on the

zzIs the air intake/exhaust port blocked?

 

Cause

power when the

zzIs the room temperature high?

 

room temperature

zzIs the filter indicator <FILTER> not lit?

 

was about 0°C

 

 

 

 

(32°F)?

 

 

 

 

zzWait at least five

zzRemove any objects that are blocking the air

zzTurn the <MAIN

 

minutes in the

intake/exhaust port.

POWER> switch to

 

current status.

zzMove the projector to a location with an

<OFF> ( page 51),

Solution

zzInstall the unit

ambient temperature of 0°C (32°F) to 45°C

and consult your

in a location

(113°F)*1 and a humidity of 20% to 80% (no

dealer.

 

with an ambient

condensation).

 

 

temperature of

zzClean the air filter unit or replace it. ( page 144)

 

 

0°C (32°F) to 45°C

 

 

 

 

(113°F)*1.

 

 

 

*1: When using the projector at high elevations (1 400 m (4 593 ft) – 2 700 m (8 858 ft) above sea level), the operating environment temperature will be 5°C (41°F) lower than the maximum limit.

When using a smoke cut filter, the temperature will be 0°C (32°F) to 35°C (95°F). However, it cannot be used at high elevations.

Note

zzIf the temperature indicator <TEMP> is still lit or flashing after taking the preceding measures, ask your dealer to repair the unit.

■■Filter indicator <FILTER>

Indicator

 

Lighting in red

 

Flashing in red

 

 

status

 

 

 

 

 

 

 

 

 

Status

The filter is clogged.

 

 

The air filter unit is not

 

 

The temperature inside or outside the projector is abnormally high.

attached.

 

 

 

 

Cause

zzIs the air filter unit

zzIs the air intake/

zzIs [HIGH ALTITUDE

zzIs the air filter unit

 

 

dirty?

exhaust port

MODE] set

attached?

 

 

 

blocked?

correctly?

 

 

 

 

zzClean the air filter

zzRemove any objects

zzWhen using the

zzAttach the air filter

 

 

 

unit or replace it.

that are blocking the

projector at high

unit.

 

 

( page 144)

air intake/exhaust

elevations 1 400 m

 

 

 

 

 

port.

(4 593 ft) – 2 700 m

 

 

 

 

 

 

(8 858 ft) sea

 

 

Maintenance

Solution

 

 

level, set [HIGH

 

 

 

 

elevations 2 700 m

 

 

 

 

ALTITUDE MODE]

 

 

 

 

 

 

( page 100) to [ON].

 

 

 

 

 

 

zzDo not use the

 

 

 

 

 

 

projector at high

 

 

 

 

 

 

(8 858 ft) or higher

 

 

 

 

 

 

above sea level.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

zzIf the filter indicator <FILTER> is still lit or flashing after taking the preceding measures, ask your dealer to repair the unit.

zzIf the filter is clogged, only one lamp may light even when [LAMP SELECT] is set to [QUAD], [TRIPLE], or [DUAL]. Cleaning the air filter unit or replacing it with a new one will turn off the indicator.

ENGLISH - 143