Chapter 6Appendix — Technical information

rrProjector control command (with sub command)

Command

Sub command

Details

Remark

VXX

LPWI1

Lamp power selection

+00001=NORMAL,+00000=ECO, +00030=AUTO

VXX

RYCI2

RGB2 input setting

+00000=RGB/YPBPR, +00001=Y/C, +00002=VIDEO

rrLens control command

Command

Sub command

Details

Remark

VXX

LNSI2

Lens H shift

+00000=Fine adjustment 1+, +00001=Fine adjustment 1-,

VXX

LNSI3

Lens V shift

+00100=Fine adjustment 2+, +00101=Fine adjustment 2-,

VXX

LNSI4

Lens focus

+00200=Coarse adjustment+, +00201=Coarse adjustment-

VXX

LNSI5

Lens zoom

 

<REMOTE 2 IN> terminal

It is possible to control the projector remotely (by external contact) from a control panel located away from the projector where remote control signals cannot reach.

Use the <REMOTE 2 IN> terminal on the connecting terminals of the projector to connect to the control panel.

Remote control Contact control

Remote control/contact control

Standby Lit

Lamp

RGB1VIDEO

RGB2HDMI

 

 

DVI-D

Installation locations in meeting rooms, etc.

 

Remote control board in another location

Pin assignments and signal names

D‑Sub 9-pin

Pin No.

Signal name

Open (H)

Short (L)

Outside view

 

 

 

 

 

 

(1)

GND

GND

(5)

(1)

(2)

POWER

OFF

ON

(3)

RGB1

Other

RGB1

 

 

 

 

(4)

RGB2

Other

RGB2

 

 

(5)

VIDEO

Other

VIDEO

 

 

(6)

HDMI

Other

HDMI

 

 

(7)

DVI‑D

Other

DVI‑D

(9)

(6)

(8)

SHUTTER *1

OFF

ON

 

 

(9)

RST/SET

Controlled by remote

Controlled by external

 

 

control

contact

 

 

 

 

*1 For PT-EZ580, PT-EW640 and PT-EX610 [AV MUTE] for PT-EW540 and PT-EX510

Attention

ff When controlling, make sure to short-circuit pins (1) and (9).

ff When pins (1) and (9) are short-circuited, the following buttons on the control panel and the remote control are disabled. Commands for RS‑232C and network functions corresponding to these functions are also disabled.

gg Power <v/b> button on the control panel or the power on <b> button, power standby <v> button, and <SHUTTER> button and <AV MUTE> button on the remote control

ff When pins (1) and (9) are short-circuited, and then any pins from (3) to (7) and the pin (1) are short-circuited, the following buttons on the control panel and the remote control are disabled. Commands for RS‑232C and network functions corresponding to these functions are also disabled.

ENGLISH - 143