34
Adjustment of phase in VS genlock mode (VS)
The adjusting video signal of the camera and the criterial external synchronizing input signal
are connected to a 2-input oscilloscope and the phase is adjusted. Follow the procedure below
to adjust the phase.
**SYNC**
H PHASE ...|...128
- +
RET TOP END
**CAMERA SETUP** 1/2
CAMERA ID OFF
ALC/ELC ALC
SHUTTER OFF
AGC ON
SENS UP OFF
SYNC INT
WHITE BAL ATW1
MOTION DET OFF
DNR HIGH
RESOLUTION HIGH
BW MODE
"CAMERA SETUP" screen
"SYNC" screen
Step 1
Provide a VS signal to the external synchro-
nizing input connector on the rear side of the
camera.
The "SYNC" setting automatically
changes to "EXT (VS)".
Step 2
Move the cursor to "EXT (VS)" and press the
setting button.
The "SYNC" screen appears.
Step 3
Connect the video output signal and external
synchronizing input signal of the camera to a
2-input oscilloscope, and move the cursor to
"HPHASE".
Step 4
Adjust the oscilloscope to the horizontal rate,
and extend the horizontal synchronizing part
of the oscilloscope.
Move the cursor horizontally to adjust the
horizontal phase with use of the right or left
button.
Adjustable range: 0 to –2.0 µs