Adjustment of phase in VS genlock mode (VS)

The adjusting video signal of the camera and the criterial external synchronizing input signal are connected to a 2-input oscilloscope and the phase is adjusted. Follow the procedure below to adjust the phase.

"CAMERA SETUP" screen

**CAMERA

SETUP** 1/2

CAMERA ID

OFF

 

 

 

 

 

ALC/ELC

ALC

 

 

 

 

SHUTTER

OFF

AGC

ON

 

 

 

 

SENS UP

OFF

SYNC

INT

 

 

 

 

WHITE BAL

ATW1

 

 

 

 

 

 

 

 

MOTION DET

OFF

DNR

HIGH

RESOLUTION

HIGH

BW MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 1

Provide a VS signal to the external synchro- nizing input connector on the rear side of the camera.

The "SYNC" setting automatically changes to "EXT (VS)".

"SYNC" screen

 

**SYNC**

 

 

H PHASE

 

 

128

......

 

 

-

+

 

RET TOP END

Step 2

Move the cursor to "EXT (VS)" and press the setting button.

The "SYNC" screen appears.

Step 3

Connect the video output signal and external synchronizing input signal of the camera to a 2-input oscilloscope, and move the cursor to "H PHASE".

Step 4

Adjust the oscilloscope to the horizontal rate, and extend the horizontal synchronizing part of the oscilloscope.

Move the cursor horizontally to adjust the horizontal phase with use of the right or left button.

Adjustable range: 0 to –2.0 µs