Notes:
•To clear the registered pixel compensation point, move the cursor to the number with which the target pixel compensation point is registered on the "PIX OFF" screen and press the setting button. The pixel compensation positioning screen appears, and then hold down the right and left buttons for more than 2 seconds simultaneously. The "PIX OFF" screen
appears, the pixel compensation point is cleared, and "*" at the right side of the number disappears.
•When an auto iris lens with video signal type is used, the pixel compensation shall be per- formed after darkening the screen.
•The auto pixel compensation function starts up to automatically detect flaws by moving the cursor to "RET" on the "PIX OFF" screen and pressing the right and left buttons simultane- ously. If there are points that seem to be flaws in the dark screen, up to 15 points are auto- matically detected and registered. In addition, once the auto pixel compensation function is activated, all of the registered pixel compensation points are cleared.
Communication configuration [COMMUNICATION]
The required communication configuration is performed to use this unit integrated into the sys- tem with a receiver.
COAX (RCV): Uses our receiver (e.g.
COAX (default): Does not use any receiver.
Default restoring [CAMERA RESET]
The settings in the setup menu are restored to the default settings.
The default settings are restored by moving the cursor to "PUSH SW" of "CAMERA RESET" and holding down the right, left, and setting buttons for more than 2 seconds simultaneously. However, the data of the registered pixel compensation points is not cleared.
Serial number viewing [SER.NO.]
The serial number of this unit appears.
49