Installations/Connections

Caution:

ONLY CONNECT WV-CL934 TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY.

Be sure to connect the grounding lead to the GND terminal.

zRotate the lens (option) clockwise slowly to mount the lens.

Important:

• For use of C-mount lens, use the C-mount adaptor (accessory).

 

ø20 mm {ø3/4"} or less

C-mount adaptor (accessory)

C mount: 4.5 mm {5/32"} or less

* Required for use of C-mount lens

CS mount: 4.5 mm {5/32"} or less

 

Optional dedicated lens

 

Lens type

Model No.

 

 

 

 

1/2-inch type {1/2"} variable

 

2 x varifocal

WV-LZ80/2

focal lens

 

 

 

 

 

 

 

 

1/2-inch type {1/2"} zoom lenses

6 x Motorized

WV-LZ81/6A

 

 

10 x Motorized

WV-LZ81/10

 

 

 

 

 

 

Note:

It is recommended to use a lens whose F number is F1.2 or greater.

When using a lens whose F number is smaller than F1.2, sharpness of image may be diminished.