8. Troubleshooting
8-16 December 2002 9700-A2-GB20-20
Network and Data Port PVC Tests do not appear on the Test menu when no PVCs
have been configured on the interface.
Network ATM Loopback Tests does not appear if no ATM links are enabled on the
network interface.
Tests can be commanded from the OpenLane SLM system using its enhanced
Diagnostic Troubleshooting graphical interface, as well as from the menu-driven
user interface.
Test Timeout Feature
A Test Timeout feature is available to automatically terminate a test (as opposed to
manually terminating a test) after it has been running a specified pe riod of time.
It is recommended that this feature be used when the FrameSaver device is
remotely managed through an inband data stream (PVC). If a test is accide ntly
commanded to execute on the interface providing management access, control
is regained when the specified time period expires, automatically termina ting the
test.
To use this feature, enable the Test Timeout configuration option, and set a
duration for the test to run in the Test Duration (min) configuration option (see

Configuring General System Options

in Chapter 4,
Configuration Options
).
NOTE:
These configuration options do not pertain to tests commanded by the DTE,
like a DTE-initiated External Loopback.