Paradyne 9788, 9720 manual Configuring General Snmp Management, General Snmp Management Options 1

Models: 9720 9788

1 340
Download 340 pages 17.41 Kb
Page 86
Image 86

4. Configuration Options

Configuring General SNMP Management

Using SNMP protocols, the FrameSaver unit can be managed as an NMS SNMP agent. You must have Level-1 access to display or configure these options.

Select General SNMP Management to add, change, or delete configuration information (see Table 4-20, General SNMP Management Options).

Main Menu Configuration Management and Communication

General SNMP Management

Table 4-20. General SNMP Management Options (1 of 2)

Determines whetherthe FrameSaverunit can be managed as an SNMP agentby an

SNMP-compatible NMS.

SNMP Management

Possible Settings: Enable, Disable

Default Setting: Enable

Enable – Can be managed as an SNMP agent.

Disable – Cannot be managed as an SNMP agent. The FrameSaver unit will not respond to SNMP messages or send SNMP traps.

Community Name 1

Possible Settings: ASCII text entry, Clear

Default Setting: Public

Specifies the first of two names that are allowed to access the objects in the FrameSaver unit’s MIB. The community name must be supplied by an external SNMP manager whenever the manager tries to access a MIB object.

ASCII text entry – Add or change Community Name 1 (maximum 255 characters).

Clear – Clears Community Name 1 field.

Name 1 Access

Possible Settings: Read, Read/Write

Default Setting: Read/Write

Specifies the type of MIB access allowed. With this access type, SNMP managers can externally access MIB objects, using Community Name 1.

Read – Allows read-only access (SNMP Get command). This includes all MIB RFCs objects specified as either read-only or read/write.

Read/Write – Allows read and write access (SNMP Get and Set commands).

4-46

December 2002

9700-A2-GB20-20

Page 86
Image 86
Paradyne 9788, 9720 Configuring General Snmp Management, General Snmp Management Options 1, Community Name, Name 1 Access