Paradyne DMD15L operation manual Opcode 2618h Command a modulators baseband loopback

Models: DMD15 DMD15L

1 201
Download 201 pages 34.1 Kb
Page 126
Image 126

DMD15/DMD15L IBS/IDR Satellite ModemUser Interfaces

<1>

Operating Mode

0 = Normal, 1 = 2047 test

Opcode: <2613h> Command a modulator's scrambler control

<1>

Scrambler Control

0 = Disable, 1 = Enable

Opcode: <2614h> Command a modulator's scrambler type

<1>

Scrambler Type

0 = None, 1 = IBS Scrm, 2 = V35_IESS, 3 = V35_CCITT, 4 =

 

 

V35_EFDATA, 5 = V35_FAIRCHILD, 6 = OM73, 7 = RS

 

 

Scrambler, 8 = V35_EFRS, 9 = TPC Scrambler

Opcode: <2615h> Command a modulator's framing

<1>

Framing

0 = No framing, 1 = 96K, 2 = 1/15, 3 = EF AUPC 1/15

Opcode: <2616h> Command a modem's external reference source

<1>

External Reference

0 = Internal, 1 = External, 2 = High stability

 

Source

 

Opcode: <2617h> Command a modulator's terrestrial loopback

<1>

Tx Terrestrial Loopback

0 = Disabled, 1 = Enabled

Opcode: <2618h> Command a modulator's baseband loopback

<1>

Tx Baseband Loopback

0 = Disabled, 1 = Enabled

Opcode: <2619h> Command a modulator’s mode

<1>

Mode

0 = Closed Net. 1 = IDR, 2 = IBS, 3 = D&I

Opcode: <261Ah> Command a modem’s external EXC clock

<4>

External EXC Clock

Binary value, 1 Hz steps. 256 kHz to 10 MHz, In 8 kHz

 

 

increments

Opcode: <261Bh> Command a modem’s external reference frequency

<4>

External Reference

Binary value, 1 Hz steps. 256 kHz to 10 MHz, In 8 kHz

 

Frequency

increments

Opcode: <261Dh> Command a modulator’s T1D4 Yellow alarm selection

<1>

T1D4 Yellow Alarm Sel.

0 = Bit 2 equal 0 for all channels

 

 

1 = Frame 12 s-bits equal 1

Opcode: <261Eh> Command a modulator’s interface type

<1>

Tx Interface Type

0 = G703-B-T1-AMI, 1 = G703-B-T1_B8ZS, 2 = G703-B-E1, 3 =

 

 

G703-B-T2, 4 = G703-U-E1, 5 = G703-U-T2, 6 = G703-U-E2, 7 = RS-

 

 

422, 8 = V.35, 9 = RS-232

Opcode: <261Fh> Command a modulator’s circuit ID

<11>

Tx Circuit ID

11 ASCII characters

Opcode: <2622h> Command Force Mod Summary Alarms

<1>

Summary Alarm

0

= Do not force. 1 = Force

Opcode: <2623h> Command Data Invert

<1>

Data Invert

0

= None, 1 = Terrestrial, 2 = Baseband, 3 = Terrestrial and

 

 

Baseband

Opcode: <2625h> Clear Latched Alarm 1 (No Data)

Opcode: <2629h> Command AUPC Local Enable

<1>

AUPC Local Enable

0 = Off, 1 = On

TM051 - Rev. 5.8

4-75

Page 126
Image 126
Paradyne DMD15L operation manual Opcode 2618h Command a modulators baseband loopback