DMD15/DMD15L IBS/IDR Satellite Modem

User Interfaces

 

 

Table 5-6. S6 Ground/Deferred – C

Switch Positions

AGC Out

1X

2X

3On

4Off

5X

Prompt - C

1X

2X

3Off

4On

5X

5.13 TERMINAL (J12)

The Terminal Port is an RS-232 Connection that is used to connect a terminal for operating and monitoring the system. It is a 9-Pin Female “D” Connector. Refer to Table 5-7 for pinouts.

Table 5-7. Terminal Port (RS-232) 9-Pin Female “D” Connector (J12)

 

Pin No.

Signal Name

Signal

Direction

 

 

 

 

 

 

 

 

3

Transmit Data

TxD

Output

 

 

 

 

 

 

 

 

2

Receive Data

RxD

Input

 

 

 

 

 

 

 

 

5

Ground

GND

---

 

 

 

 

 

 

 

 

7

Request to Send

RTS

Input

 

 

 

 

 

 

 

 

8

Clear to Send

CTS

Input

 

 

 

 

 

 

 

5.14 REMOTE (J13)

The Remote Port is a RS-485 Connection for remote monitor and control of the modem. It is a 9- Pin Female “D” Connector. Refer to Table 5-8 for pinouts.

Table 5-8. Remote Port RS-485 9-Pin Female “D” Connector (J13)

 

Pin No.

Signal Name

Signal

Direction

 

 

 

 

 

 

 

 

1

Transmit Data B

RS-485 TxD-B

Output

 

 

 

 

 

 

 

 

2

Transmit Clock A

TxC-A

Output

 

 

 

 

 

 

 

 

3

Transmit Clock B

TxC-B

Output

 

 

 

 

 

 

 

 

4

Receive Clock A

RxC-A

Input

 

 

 

 

 

 

 

 

5

Signal Common

Common

---

 

 

 

 

 

 

 

 

6

Transmit Data A

RS-485 TxD-A

Output

 

 

 

 

 

 

 

 

7

Receive Clock B

RxC-B

Input

 

 

 

 

 

 

 

 

8

Receive Data B

RS-485 RxD-B

Input

 

 

 

 

 

 

 

 

9

Receive Data A

RS-485 RxD-A

Input

 

 

 

 

 

 

 

TM051 - Rev. 5.8