DMD15/DMD15L IBS/IDR Satellite Modem

 

 

5.11 STATUS (J11)

The Modem Status Interface Port is a 15-Pin Female “D” Connector. Refer to Table 5-4 for pinouts.

Table 5-4. STATUS Data Port 15-Pin Female “D” Connector (J11)

 

Pin No.

Signal Name

Signal

Direction

 

 

 

 

 

 

 

 

1

Mod Fault - C

MF-C

No Direction

 

 

 

 

 

 

 

 

2

Mod Fault – NC

MF-NC

No Direction

 

 

 

 

 

 

 

 

3

Mod Fault – NO

MF-NO

No Direction

 

 

 

 

 

 

 

 

4

Demod Fault - C

DF-C

No Direction

 

 

 

 

 

 

 

 

5

Demod Fault – NC

DF-NC

No Direction

 

 

 

 

 

 

 

 

6

Demod Fault – NO

DF-NO

No Direction

 

 

 

 

 

 

 

 

7

Common Equipment Fault - C

CEF-C

No Direction

 

 

 

 

 

 

 

 

8

Common Equipment Fault – NC

CEF-NC

No Direction

 

 

 

 

 

 

 

 

9

Common Equipment Fault – NO

CEF-NO

No Direction

 

 

 

 

 

 

 

 

10

Prompt – NO

SP1-NO

No Direction

 

 

 

 

 

 

 

 

11

Prompt – NC

SP1-NC

No Direction

 

 

 

 

 

 

 

 

12

Deferred – NO

SP2-NO

No Direction

 

 

 

 

 

 

 

 

13

Deferred – NC

SP2-NC

No Direction

 

 

 

 

 

 

 

 

14

AGC Out/Prompt – C (refer to

SP1C/AGC

No Direction

 

 

 

Table 5-5)

 

 

 

 

 

 

 

 

 

 

15

Ground/Deferred – C (refer to

SP2-C/GND

No Direction

 

 

 

Table 5-6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5-5. S6 AGC Out/Prompt – C

 

 

 

 

 

Switch Positions

 

 

 

 

 

 

 

 

 

AGC Out

1On

2Off

3X

4X

5X

Prompt - C

1Off

2On

3X

4X

5X

5-6

TM051 – Rev. 5.8