Model 3196RC T-DAC User Manual

5 • Troubleshooting and maintenance

 

 

Table 8. LED definitions (Continued)

LED

Location

Color

Status

Meaning

 

 

 

 

 

SYSTEM

Front

Green

Flash-

The Model 3196RC is operating normally. No action rec-

 

panel

 

ing

ommended.

 

 

 

Off

The Model 3196RC is not functioning properly. As soon

 

 

 

 

as possible, unplug both power cables from the Model

 

 

 

 

3196RC, wait 30 seconds, then plug the cables back

 

 

 

 

into the Mode 3196RC to see if the problem disappears.

 

 

 

 

If the SYSTEM LED remains lit after the Model 3196RC

 

 

 

 

completes the power-up cycle, contact Patton Technical

 

 

 

 

Support to determine whether the T-DAC needs to be

 

 

 

 

replaced.

 

 

 

 

 

ETHERNET

Front

Green

On solid

Link status is nominal for the Ethernet port. No action recom-

 

panel

 

 

mended.

 

 

 

Off

A valid link has not been detected.

 

 

 

 

Verify that an Ethernet cable is plugged into the hub, switch,

 

 

 

 

or workstation and the Ethernet port of the Model 3196RC.

 

 

 

 

Verify that the hub, switch, or workstation is powered on.

 

 

 

 

Verify that the correct straight-through or cross-over cable is

 

 

 

 

being used, depending on whether you are connecting to a

 

 

 

 

workstation (PC), hub, or switch.

 

 

 

 

Replace the cable. If the problem still exists, contact Patton Tech-

 

 

 

 

nical Support to determine if the T-DAC should be replaced.

CLK SOURCE

Front

Green

On solid

The 3196RC is set as the Master Clock source. No action rec-

 

panel

 

 

ommended.

 

 

 

Flashing

The 3196RC is set as the secondary clock source. No action

 

 

 

 

recommended.

 

 

 

 

 

 

 

 

Off

The 3196RC is set as the slave, getting its clock from the H.110

 

 

 

 

Bus. No action recommended.

CLK ERROR

Front panel

Yellow

On solid

Master Clock source has been lost and the 3196RC is using the

 

 

 

 

secondary source for its clock.

 

 

 

 

 

 

 

 

Flashing

Master Clock source and the Secondary Clock source have been

 

 

 

 

lost and the 3196RC is using its internal crystal for its clock.

 

 

 

Off

No clock errors currently detected.

 

 

 

 

No action recommended.

TEST MODE

Front panel

Green

On solid

One or more iDSL ports or T1/E1 ports is in test mode.

 

 

 

 

No action recommended.

 

 

 

Flashing

One or more of the iDSL ports or the T1/E1 ports is in test mode

 

 

 

 

and errors have been received.

 

 

 

 

 

 

 

 

Off

None of the iDSL ports is operating in test mode.

 

 

 

 

No action recommended.

 

 

 

 

 

Fault analysis

73

Page 73
Image 73
Patton electronic 3196RC user manual System