2 • Hardware installation

 

 

Connecting the iDSL ports

The remote (CPE) iDSL modems are connected to the T-DAC via the RJ-21X cable (see figure 12).

Pin 1

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50-pin TELCO Male

 

 

26

50

 

Figure 12. RJ-21X connector

1.Connect the RJ-21X connector of the cable into the 50-pin RJ-21X receptacle on the rear of the 3196RC.

2.The other end of the cable has 25 non-terminated twisted-pairs for connection to punch-down blocks. Only 16 of the 25 pairs (see table 5) will be used since there are 16 iDSL modem connections, each requir- ing one twisted pair. Select the twisted-pairs which will be used for active iDSL modem connections and terminate each pair on the punch-down blocks.

Table 5. Band Marked Color Code

DSL Port

50 Pin Positions

Wire Color Code

 

 

 

Port 1

1

Blue/White

26

White/Blue

 

Port 2

2

Orange/White

27

White/Orange

 

 

 

 

Port 3

3

Green/White

28

White/Green

 

Port 4

4

Brown/White

29

White/Brown

 

 

 

 

Port 5

5

Slate/White

30

White/Slate

 

Port 6

6

Blue/Red

31

Red/Blue

 

 

 

 

Port 7

7

Orange/Red

32

Red/Orange

 

Port 8

8

Green/Red

33

Red/Green

 

 

 

 

Port 9

9

Brown/Red

34

Red/Brown

 

Port 10

10

Slate/Red

35

Red/Slate

 

 

 

 

Port 11

11

Blue/Black

36

Black/Blue

 

 

 

 