Table 3. LED definitions (Continued)

 

 

 

 

LED

Color

Status

Meaning

 

 

 

 

CLK SOURCE

Green

On solid

The 3196RC is set as the Master Clock source.

 

 

Flashing

The 3196RC is set as the secondary clock source.

 

 

 

 

 

 

Off

The 3196RC is set as the slave, getting its clock from the H.110 Bus.

CLK ERROR

Yellow

On solid

Master Clock source has been lost and the 3196RC is using the secondary source

 

 

 

for its clock.

 

 

 

 

 

 

Flashing

Master Clock source and the Secondary Clock source have been lost and the 3196RC

 

 

 

is using its internal crystal for its clock.

 

 

Off

No clock errors currently detected.

TEST MODE

Green

On solid

One or more iDSL ports or T1/E1 ports is in test mode.

 

 

Flashing

One or more of the iDSL ports or the T1/E1 ports is in test mode and errors have

 

 

 

been received.

 

 

 

 

 

 

Off

None of the iDSL ports is operating in test mode.

WANa

Green

On solid

Indicates the given port is activated, linked, and operating normally.

 

 

Single

Indicates that the Model 3196RC is detecting the network, but is unable to synchro-

 

 

Flash

nize with it.

 

 

Double

Indicates an error on any of the T1/E1 links.

 

 

Flash

 

 

 

 

 

 

 

Off

Indicates no T1/E1 links are in use.

DSL

Green

On solid

The port is activated, linked, and operating normally.

CONNECTION

 

 

 

 

Flashing

The port is activated but not linked or in an error state.

(LEDs 1–16)

 

 

Off

The iDSL port has not been configured to establish a link.

 

 

 

 

 

 

READY

Blue

On

Card ready for removal from cPCI chassis.

 

 

Off

Card not ready for removal from cPCI chassis.

 

 

 

 

a.The WAN LED provides status indications for the WAN links established via the T1/E1 ports on the rear blade of the 3196RC.