Model 3202 Getting Started Guide

1 • General information

 

 

Reset button

To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset button. The Model 3202 will restart with the current startup configuration.

To restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power LED starts blinking. The unit will restart with factory default configuration.

To restart the unit in bootloader mode (to be used only by trained RocketLink technicians)—Start with the unit powered off. Press and hold the Reset button while applying power to the unit. Release the Reset button when the Power LED starts blinking so the unit will enter bootloader mode.

Ground terminal

The marked lug or terminal should be connected to the building protective earth bus.The func- tion of protective earth does not serve the purpose of providing protection against electrical shock, but instead enhances surge suppression on the DSL lines for installations where suitable bonding facilities exist.The connector type is M3 machine screw.

Model 3202 rear panel

21

Page 21
Image 21
Patton electronic 3202 manual Reset button, Ground terminal