Model 3202 Getting Started Guide

5 • Console and Telnet configuration

 

 

Mode

There are two types of G.SHDSL mode:

STU-C: Central Office (CO) terminal

STU-R:Customer Premise Equipment (CPE)

Link

Select the line type for your model. Line type means how many wires you want to use on the DSL connection. For example, you can select 2-wire, 4-wire or 8-wire line type for the 8-wire model.

Model

Type

Table 19. Line Type Chart

 

 

 

Line Type

 

 

 

 

 

 

 

 

2-wire

4-wire

8-wire

 

2-wire model

 

 

 

 

 

 

 

4-wire model

 

 

8-wire model

Annex Type

Enter the appropriate Annex type. Annex AF describes the transmission and performance requirements for North America. Annex BG describes performance and transmission requirements for Europe.

TCPAM Type

TCPAM (Trellis Coded Pulse Amplitude Modulation) is the standard used for line coding. Select the TCPAM type. Auto is the default option for TCPAM.

Maximum Main Rate

Select the DSL rate for your model. The main rate is the multiple of 64kbps, 128kbps, or 256kpbs- depending on your model type. Use Table 20 to determine the best main rate for your model.

Table 20. Main Rate Chart

Model Type

Multiple

TCPAM-16

TCPAM-32

TCPAM-64

= 3–60

= 12–89

= 90–177

 

 

 

 

 

 

 

2-wire model

64

192–3840

768–5696

5760-11328

 

 

 

 

 

4-wire model

128

384–7680

1536–11392

11520-22656

 

 

 

 

 

8-wire model

256

768–15360

3072–22784

23040-45312

 

 

 

 

 

SNR Margin

SNR margin is an index of line connection quality. Generally, you won’t need to change the SNR Margin. You can view the actual SNR margin in status command menu.You will experience better line connection quality for larger SNR margin values.