Patton electronic manual Grounding the Model 3202 and connecting power

Models: 3202

1 106
Download 106 pages 9.27 Kb
Page 30
Image 30
Grounding the Model 3202 and connecting power

Model 3202 Getting Started Guide

3 • Hardware installation

 

 

Grounding the Model 3202 and connecting power

In connecting to the power source, it is important to establish a good grounding connection first, then the power connection. Do the following:

1.Assemble a ground wire using #10 AWG wire with green-colored insulation and two ring terminals. Make the wire long enough to reach one of the following earth ground sources:

The building ground rod (generally located at the site’s main service entrance)

A sprinkler system pipe

A cold-water pipe

Building structural steel

4

LINE

Grounding stud

Figure 6. Grounding stud

2.Install the grounding wire between the grounding stud (see figure 6) and the grounding source.

3.Connect the power adapter to the DC 9V port on the Model 3202, and then connect to the power source.

WARNING

WARNING

Mains Voltage: Do not open the case the when the power cord is attached. Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.

The Model 3202 is not shipped with power cables. For AC powered units, ensure that the power cable used meets all applicable standards for the coun- try in which it is to be installed, and that it is connected to a wall outlet which has earth ground.

The power supply automatically adjusts to accept an input volt- age from 100 to 240 VAC(50/60 Hz).

IMPORTANT

Installing the Model 3202

30

Page 30
Image 30
Patton electronic manual Grounding the Model 3202 and connecting power