SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD> <CLOCK> <EVENT>
BACK
EXIT
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY ALARM ACTION ACTIVATE AUX ALARM CONTACT <EDIT SCHEDULE>
BACK
EXIT
5.Set the auxiliary to activate:
a.Use the joystick to position the cursor beside ACTIVATE AUX.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view the following available selections. NO (default): Not activated.
1:An alarm action will close AUX 1.
2:An alarm action will close AUX 2.
d.Press Iris Open to enter selection.
Note: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the AUX1/AUX is set up as momentary, then it will be activated each time a new alarm is activated.
6.Set the alarm contact:
a.Use the joystick to position the cursor beside ALARM CONTACT.
b.Press Iris Open. The cursor moves to the right.
c.Move the joystick up or down to view the following available selections.
N/O (default): Normally open.
N/C: Normally closed.
d.Press Iris Open to enter selection.
Note: The alarm contact feature is functional and available for 16X and 18X models only if the dome drive is installed in a Spectra III SE or Spectra IV SE back box.
7.To edit the alarm schedule:
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 80) with the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also, the Holiday feature cannot be accessed from the Edit Schedule menu.
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on page 83.
* This setting applies only to Pressurized Spectra IV dome systems.
70 |