Pelco C3412M-D manual Alert, Repeat

Models: C3412M-D

1 100
Download 100 pages 17.63 Kb
Page 73
Image 73

ALERT

SPECTRA IV

LANGUAGE

<SYSTEM INFORMATION> <DISPLAY SETUP>

<DOME SETTINGS>

ACK ALERT

RESET CAMERA

CYCLE CAMERA POWER REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<WINDOW BLANKING> <ALARMS>

<AUX>

<TITLE TEXT> <ALERT> <CLEAR> <PASSWORD> <CLOCK> <EVENT>

BACK

EXIT

ALERT

REPEAT ACK ACTION ACTIVATE AUX <CURRENT READING> RESET ALERT

BACK

EXIT

Note: The Alert option applies only to Pressurized Spectra IV dome systems. Spectra IV systems that are not pressurized will not display this menu item.

Sensors strategically placed inside the pressurized dome system continually monitor pressure, temperature, and dew point. If internal conditions reach unacceptable levels, an alert message appears on the screen describing the alert condition. For example, if pressure drops below 1 psig, LOW PRESSURE is displayed on the monitor.

The following system conditions will trigger an alert message:

System Condition

Alert Message

Temperature is above 140°F (60°C)

HIGH TEMPERATURE

Temperature is below -40°F (-40°C)

LOW TEMPERATURE

Pressure is above 13 PSIG

HIGH PRESSURE

Pressure is below 1 PSIG

LOW PRESSURE

The difference between the temperature and

DEW POINT (HIGH HUMIDITY)

the dew point is less than or equal to 3°C.

 

The alert message will be repeatedly displayed until the system controller acknowledges the alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message changes to the programmed acknowledge action (ACK ACTION). If the alert condition remains active after a period of time, the alert message reappears on the monitor, restarting the alert message cycle. This cycle will continue to repeat until the alert condition is resolved.

REPEAT

This setting programs how often an alert message is repeatedly displayed until the system controller acknowledges the alert condition. The following are the settings:

CONSTANT: The alert message is continuously displayed on the monitor until acknowledged.

15 MIN: The alert message is displayed every 15 minutes for a 15-second duration until acknowledged.

30 MIN: The alert message is displayed every 30 minutes for a 15-second duration until acknowledged.

60 MIN: The alert message is displayed every 60 minutes for a 15-second duration until acknowledged.

OFF: The alert message is disabled and will not be displayed on the monitor.

C3412M-D (12/08)

73

Page 73
Image 73
Pelco C3412M-D manual Alert, Repeat