SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION> <DISPLAY SETUP>
<DOME SETTINGS> ACK ALERT
RESET CAMERA
CYCLE CAMERA POWER REBOOT SYSTEM
EXIT
DOME SETTINGS
<CAMERA>
<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>
<WINDOW BLANKING> <ALARMS>
<AUX>
<TITLE TEXT> <ALERT>
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
BACK
EXIT
ALERT
REPEAT ACK ACTION ACTIVATE AUX <CURRENT READING> RESET ALERT
BACK
EXIT
CURRENT READING
TEMPERATURE
DEWPOINT
PRESSURE
REFRESH
BACK
EXIT
ACK ACTION
Set ACK ACTION to program the frequency at which an alert message is displayed after the alert condition has been acknowledged. The following settings are available:
ALWAYS ON: The alert message is displayed until alert conditions are cleared.
OFF 8 HRS: The alert message is turned off for 8 hours. Message returns after 8 hours if the alert condition persists.
OFF 24 HRS: The alert message is turned off for 24 hours. Message returns after 24 hours if the alert condition persists.
OFF 48 HRS: The alert message is turned off for 48 hours. Message returns after 48 hours if the alert condition persists.
ACTIVATE AUX
This setting activates an auxiliary when an alert condition exists. Settings include the following options:
NONE (default): Not activated.
1:An alert condition will close AUX 1.
2:An alert condition will close AUX 2.
CURRENT READING
The Current Reading menu displays the existing status of temperature, pressure, and dew point inside the dome system. An arrow displayed to the left of a menu item denotes that an alert condition exists.
An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is below the threshold.
The high temperature alert occurs if the temperature is above 140°F (60°C).
The low temperature alert occurs if the temperature is below
The high pressure alert occurs if the pressure is above 13 PSIG.
The low pressure alert occurs if the pressure is below 1 PSIG.
The dew point (high humidity) alert occurs if the difference between the temperature and the dew point is less than or equal to 3°C.
Note: The normal operating temperature inside the unit will be greater than the temperature outside the back box due to the heat emitted by the system’s electronics.
RESET ALERT
Reset alert clears the alert condition and removes the alert label from the monitor. The system automatically checks internal conditions 60 seconds after reset. If conditions are still unacceptable, the alert label reappears on the screen indicating further corrective action is required.
74 |