5.3 REAR PANEL

WARNING: The included power cord is used for 120 VAC, 60 Hz. Never connect the power cord to any outlet or power supply having a different voltage or frequency.

1

2 4 6 9 A

 

 

 

3

5

7 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET RST REC GND ALM MODE

 

CLK CALL

 

IN

 

 

 

OUT

 

RESET

 

 

 

 

 

 

 

 

 

 

 

ÉMIC

INOUT

AUDIO

REMOTE

IN

OUT

 

VIDEO

 

 

G F E

D C B

 

NOTE: Make sure the power cord is unplugged before making any rear terminal connections.

1.

AC power socket

8.

CLK (clock) OUT terminal

 

The power cord plugs into this socket. Insert the cord firmly.

Output terminal to control an external camera switcher, such

 

 

 

as the MX4000 Series Genex™ Multiplexer.

2.

SET IN terminal

 

 

(Alarm) input terminal to start alarm recording. Connect the alarm sensor here.

3.RST (reset) IN terminal

Input terminal to stop alarm recording when ALARM REC DURATION in the Recording Set Up menu is set to MAN1. Connect the alarm reset switch here. You can also use this terminal to set the on-screen clock when set to any mode other than MAN1.

4.REC IN terminal

Input terminal to start/stop recording. You can also use this terminal for series recording (refer to Section 8.1.5) or syn- chronous recording (Section 8.1.6).

5.GND (ground) OUT terminal

Connect the ground lead here when a lead connected to other terminals requires a ground.

6.ALM (alarm) OUT terminal

Output terminal to an external device to indicate an alarm is being recorded.

7.MODE OUT terminal

Output terminal to indicate the VCR’s mode of operation, which can be selected by setting the MODE OUT in the Rear Terminal menu.

9.CALL OUT terminal

Output terminal to indicate when the tape has finished re- cording or that there was a problem during recording.

10.RESET button

Press to erase the present time, alarm recording list, power loss list, and the number of tape uses. Power to the VCR is cut off while the button is pressed. If there is a tape in the VCR and the button is released, the power indicator will light and the tape will fast forward for a few seconds. The VCR will then turn off.

11.REMOTE jack

The remote control unit is not supplied.

12.VIDEO OUT connector

Output connector for video signal (BNC connector).

13.VIDEO IN connector

Input connector for video signal (BNC connector).

14.AUDIO OUT connector

Audio output connector (RCA pin).

15.AUDIO IN connector

Audio input connector (RCA pin).

16.MIC IN jack

Input jack for a microphone rated at 600-ohms impedance.

Figure 5. Rear View

Pelco Manual C651M (7/99)

17

Page 17
Image 17
Pelco TLR2096 operation manual Rear Panel