8.2.3 Avoid Mistakes When Using The Timer
Refer to Table G if you get an error when pressing the TIMER REC button.
Table G. Timer Recording Troubleshooting
SYMPTOM | FAULT |
|
|
|
| ACTION |
TIMER REC indicator | • A tape is not inserted. | 1. | Press the TIMER REC | |||
flashes. | • A tape is loaded with the |
| button. | |||
|
|
|
|
|
| |
| erasure prevention tab | 2. | Correctly set the timer | |||
| removed. |
| program. | |||
| • Date, time, or timer | 3. | Press the TIMER REC | |||
| recording time is not set. |
| button and confirm the | |||
| • A menu is being |
| TIMER REC indicator | |||
|
| ( |
|
| ) is illuminated. | |
| programmed. |
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
8.3 ALARM RECORDING
You can switch from all recording modes to the
•You can switch to alarm recording by applying the alarm input signal from the alarm sensor during recording in 2H, 6H, L18H, 72H, or 96H.
•Set the alarm recording mode and alarm recording period in the Recording Set Up menu. Refer to Section 6.7 for instructions.
•The index signal is automatically recorded when alarm recording begins (IN- DEX indicator flashes on the fluorescent display).
•To record the index signal, the first 15 seconds of the alarm recording are in 2H or 6H mode.
•If another alarm input signal is applied to the SET IN (alarm input) terminal while the index signal is being recorded (for 15 seconds), a new alarm record- ing will not be triggered.
ALARM INPUT
2H - 96H | 2H or 6H | 2H | |||
RECORDING | RECORD- | RECORDING | |||
|
| ING |
|
| |
|
|
|
|
| |
|
| 15sec |
| ||
NORMAL mode |
|
| ALARM mode | ||
|
|
|
|
|
|
2H - 96H
RECORDING
NORMAL mode
Figure 22. Switching From Normal To Alarm Mode And Back
Pelco Manual C651M (7/99) | 35 |