Error Codes in the UltraRes Control Software

Error Code

Meaning

Display Behavior and Solution

 

 

 

DC Power Supply

One of the DC-DC converters on

The display will not start up if this

Failure

the main board of the display has

occurs.

 

failed.

Solution: The main board needs to

 

 

be replaced.

 

 

 

FPGA Initialization

One of the FPGAs on the main

There are two possible causes: one

Failure

board did not start up correctly.

of the FPGAs has corrupt code or is

 

 

damaged.

 

 

Solution: First check the FPGA

 

 

status LEDs on the main board. If

 

 

one is not blinking, that FPGA

 

 

didn’t start up. The FPGA code may

 

 

need to be programmed again.

 

 

Solution: If reprogramming an

 

 

FPGA doesn’t work, it is likely the

 

 

FPGA is damaged. If this is the case,

 

 

the main board needs to be

 

 

replaced.

 

 

 

Calibration

The main board could not

It is likely that the calibration

EEPROM Failure

communicate with the calibration

EEPROM cable is disconnected.

 

EEPROM.

Solution: Connect the EEPROM

 

 

cable.

 

 

 

Planar UltraRes User Manual

143

Page 143
Image 143
Planar 020-1229-03A user manual Eeprom