Environmental Specifications

Specification

Maximum

Minimum

Optimal

Notes

 

 

 

 

 

Temperature

 

 

 

 

operating

40° C

0° C

20-25° C

All performance specifications are

 

104° F

32° F

 

maintained within this temperature range.

 

 

 

 

 

non-operating

60° C

–20° C

20° C

 

 

140° F

–4° F

+/- 10° C

 

 

 

 

 

 

Altitude (barometric pressure)

3000m

 

 

 

 

 

 

 

 

Humidity

 

 

 

 

operating

85% R.H.

 

 

non-condensing

non-operating

90% R.H.

 

 

non-condensing

 

 

 

 

 

Low line voltage range

 

 

100-120V

 

 

 

 

 

 

High line voltage range

 

 

200-240V

 

 

 

 

 

 

Line frequency range

 

 

49-61Hz

 

 

 

 

 

 

Acoustic Noise

 

 

 

Fanless

 

 

 

 

 

Inrush current

 

 

60A

 

 

 

 

 

 

Power consumption

 

 

 

 

Standby

 

 

< 0.5W

 

84” - Normal operation

550W

 

465W typ.

550W x 3.42 BTU = 1881 BTU/hr max.

 

 

 

 

465W x 3.42 BTU = 1590 BTU/hr typ.

98” - Normal operation

600W

 

520W typ.

600W x 3.42 BTU = 2052 BTU/hr max.

 

 

 

 

520W x 3.42 BTU = 1778 BTU/hr typ.

 

 

 

 

 