Polycom DOC2560A Slot - the MPM/MPM+/MPMx card that the RTM ISDN, RMX 4000 MPM1/MPM2/MPM3/MPM4

Models: DOC2560A

1 188
Download 188 pages 15.64 Kb
Page 70
Image 70
—Slot – the MPM/MPM+/MPMx card that the RTM ISDN /

Chapter 2-First Time Installation and Configuration

Slot – the MPM/MPM+/MPMx card that the RTM ISDN /

RTM ISDN 1500 card is connected to (RMX 2000: MPM 1/MPM2

RMX 4000: MPM1/MPM2/MPM3/MPM4).

On the RMX 1500, the Slot field does not appear.

Service – the ISDN/PSTN Network Service to which the span is assigned.

Clock Source indicates if ISDN signaling synchronization is being supplied by the Primary or Secondary clock source. The first span to synchronize becomes the Primary clock source.

State – the System Alert level of the span (Major, Minor). If there are no span related alerts, this column contains no entries.

30Click the check boxes in the Attached field to attach spans (E1 or T1 PRI lines) to the network service named in the Network Service Name field.

The Spans Table displays the configuration of all spans and all ISDN network services in the system.

When using the Fast Configuration Wizard during First Entry Configuration, you are defining the first ISDN/PSTN Network Service in the system. Spans can only be attached to this service.

Additional ISDN/PSTN Network Services can be defined by using the ISDN/PSTN Network Services > New PSTN Service button in the RMX Web Client.

Spans can be attached to, or moved between ISDN network services by using the ISDN/PSTN Network Services > ISDN Properties > Spans tab in the RMX Web Client.

Each ISDN RTM card can support either 7 E1 or 9 T1 PRI lines (E1 and T1 connections cannot be used simultaneously).

31Click Next.

2-38

Page 70
Image 70
Polycom DOC2560A manual Slot - the MPM/MPM+/MPMx card that the RTM ISDN, RMX 4000 MPM1/MPM2/MPM3/MPM4, 2-38