4–Non-Interactive Commands
Command Summary
4-30 SN0054614-00 K
Run Adapter Diagnostics Read-write Buffer Test
The {(-ex | exclude) <target wwpn>} parameters specify a device that
will be excluded from the read/write buffer test.
The system shows the following information after a read/write buffer test
completes:
Loop ID/status
Data miscompare
Link failure
Loss of sync
Loss of signal
Invalid CRC
Table4-11 lists the <param name>, <param alias>, and <param value>
options.
Table 4-11. Diagnostics Parameters
Name
<param name>
Alias
<param alias>
Value
<param value> Description
DataPattern DP Test pattern in hex formata
Customized (00–FF)
Random pattern
CRPATb
CJTPATc
CSPATd
aValid two-character case-insensitive hexadecimal patterns.
bCompliant random data pattern in a valid FC frame, as defined by the ANSI document Methodologies for Jitter and
Signal Quality Specification - MJSQ Annex A - Test bit sequences.
00, 55, 5A, A5, AA, FF (see
Tabl e 4-1 2)
Loopback test only
Loopback test only
Loopback test only
DataSizee DS 8, 16, 32, 64, 128, 256, 512,
1024, 2048
Actual data transferred during
any given pass of the test
TestCountfTC 0–65535
0–10,000
Loopback test only
Read/write buffer test only
TestIncrementgTI 1–65535
1–10,000
Loopback test only
Read/write buffer test only
OnError OE 0–2 0 = ignore
1 = stop
2 = loop on error
Table Notes