USING SUPPLEMENTAL OXYGEN

USING SUPPLEMENTAL OXYGEN

If oxygen is being added at the mask, the oxygen tube is attached to the mask port. Refer to your mask manual for full instructions.

Up to 15 L/min of oxygen can be added at the mask when using an AUTOSET CS2 system.

Oxygen tube

Oxygen tube

ENGLISH

Figure 11: Oxygen tube attached to Mirage FFMS2 and Ultra Mirage masks

WARNINGS

! If oxygen is used with this device, the oxygen flow must be turned off when the device is not operating.

Explanation: When the device is not in operation, and the oxygen flow is left on, oxygen delivered into the ventilator tubing may accumulate within the device enclosure and create a risk of fire.

Always begin AUTOSET CS2 therapy before the oxygen supply is turned on.

Always turn the oxygen supply off before stopping AUTOSET CS2 therapy.

Oxygen supports combustion. Oxygen should not be used while smoking or in the presence of an open flame.