Area Editing (Option)

Notes for Designating Areas

The number of the points, areas, and groups that can be designated

 

Note

 

Maximum number of points: 500

 

In Right Angle Polygon mode, Polygon mode, or Line mode, the maximum

 

number of points for one area is 30.

 

The number of areas that can be designated is as follows:

 

• Rectangle mode: maximum 250 areas

 

• Right Angle Polygon mode, Polygon mode, Line mode: 500 points maxi-

4

mum. For example, if 10 points are designated for each area, the maximum

number of areas that can be designated is 50.

Closed Loop mode, Multi-Closed Loop mode: maximum 500 areas

Maximum number of groups: 20 (“Group” means a set of areas that you want to do same editions.)

If you want to designate area shape like an acute angle by using Polygon mode or Line mode, see the following instructions.

Use two separate lines to create angle(A).

The first designated point(1) and the next designate point(3) should have distance of more than 4mm(0.2")(B).

*:4mm(0.2”)

Note

Do not designate an area or line which overlaps part of another area or line. If an area overlaps another one, the job settings specified last will be applied to the overlapped portion or those areas might not be copied.