EYE-QTMAutoconvergence

TOUCH-UP ON TIMER

This option allows the static convergence to be carried out auto- matically after a user-defined time, which can be programmed in hours and/or minutes.

To program the touch-up on Timer:

Push up or down keys of the control disc to highlight ON TIMER: off;

Press the <ENTER> button to switch it to ON and the preset time will be displayed;

Press the <TEXT> button to enter the TOUCH-UP TIMER menu;

Push left or right keys of the control disc to highlight the digit to be changed;

Use the numeric keys to enter a desire value;

Press the <ENTER> button to confirm and the EYE-QTMSETUP menu will return on the screen; or press the <EXIT> button to leave the preset value untouched and return to the EYE-QTMSETUP menu.

Press the <EXIT> button to return to the EYE-QTMmenu.

When one adjust geometry by hand, a reference screen and a refer- ence pattern are required. There are a lot of possibilities for a ref- erence screen. A test pattern for a video test disc is normally used. See geometry section of manual for more information. Once a selection of a reference screen and a reference pattern is made, adjusting geometry is only a matter of converging these two ele- ments.

EYE-QTMrequires a reference for adjusting geometry. The simplest way to have a reference screen is to adjust one source by hand, which then serves as a reference for all other sources. After adjust- ing a source, the reference is learned by EYE-QTMand stored in non-volatile memory. Having this Reference Source in memory EYE-QTMcan adjust all other sources to have the same geometry as the Reference Source.

EYE-Q

 

TOUCH UP

AUTOCONVERGENCE

QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

Select with

or

then <ENTER>.

<EXIT> to return

 

EYE-Q SETUP

 

 

FOCUS THE LENS

 

 

CENTER THE CAMERA

 

 

CONFIGURATION: rear/front

 

 

LEARN REFERENCE

 

 

TOUCH-UP OPTIONS:

 

 

TOUCH-UP OPTIONS

 

ON SOURCE SWITCH : on/off

 

ON TIMER : on/off

 

-h.- min.

 

 

Select with

or

 

then <ENTER>.

 

<EXIT> to return

EYE-Q SETUP

 

FOCUS THE LENS

 

CENTER THE CAMERA

 

CONFIGURATION: rear/front

 

LEARN REFERENCE

 

TOUCH-UP OPTIONS:

 

Select with

or

 

then <ENTER>.

 

<EXIT> to return

 

REFERENCE SOURCE

Before any geometric adjustment can be done, the user Must learn a Reference Source. This process is ONLY DONE ONCE since the Reference will be stored in non-volatile memory. If however, the projector is moved from its position, then the Learn Reference pro- cedure must be repeated. After learning a Reference do not touch the camera (for focusing and centering).

If using multi-aspect ratios, a Reference Geometry must be done for each aspect ratio.

ADJUSTING OTHER SOURCES

Once a Reference Source is in memory, other sources are aligned with the same geometry as the Reference Source. If no Reference Source is learned, the resulting geometry will be unpredictable.

10-8

Page 58
Image 58
Runco DTV-947 manual TOUCH-UP on Timer, Reference Source, Adjusting Other Sources