EYE-QTMAutoconvergence

NO PATTERN ERROR

After starting up the automatic convergence, the projector will start to calculate and locate 5 horizontal and 5 vertical lines which are used to divide the screen into 25 areas.

If the projector does not succeed in finding the pattern, it will try two time. If the two attempts fail, the projector will quit the process and display the Error menu.

The AUTOCONVERGENCE selection will be followed by the error window displaying the following possibilities.

Error occurred, please check:

the lens cap is removed

the lens of the camera is correctly focused;

the camera is correctly centered;

if hardware problems exist, do diagnostics;

the ambient light is too high;

the blanking adjustments are correct;

Press the <ENTER> button to start EYE-QTMdiagnostics (refer to page for full details on EYE-QTMdiagnostics, please note that this option may vary in selection with different pro- jectors).

STATUS REPORTING FORCED BREAK

After starting up the automatic convergence, if unexpected trouble such as the interruption of source input occurs, the projector will quit the process and display the AUTOCONVERGENCE menu on the screen.

The status line in the AUTOCONVERGENCE menu will display the following message:

EYE-Q

 

TOUCH UP

AUTOCONVERGENCE

QUICK AUTOPICTURE

FULL AUTOPICTURE

EYE-Q SETUP

EYE-Q DIAGNOSTICS

Select with

or

then <ENTER>.

<EXIT> to return

Error occurred

check :

*lenscap removed *focus camera *center camera *ambient light too high

*hardware problem : press <ENTER> to start diagnostics

*blanking adjustments are correct

Press <ENTER>. to start EYE-Q diagnostics or <EXIT> to return

Status: Forced break

The possible causes of such an error:

The source is disconnected during the convergence:

On the screen a message “Source not available” will be dis- played and projector waits until the source is reconnected or selected;

Switching sources during the convergence:

After the source is available again, the AUTOCONVER- GENCE menu will be displayed the status line reporting “Forced Break.”

AUTOCONVERGENCE

ON CURRENT SOURCE:

ALIGN

 

ALIGN FROM MIDPOSITION

ON ALL SOURCES: (XX)

TOUCH-UP

ALIGN

 

ALIGN FROM MIDPOSITION

STATUS:

 

forced break

 

Select with

or

then <ENTER>.

<EXIT> to return