EYE-QTMAutoconvergence

EYE-QTMDIAGNOSTICS

This option allows a check-up of the EYE-QTM

NOTE: Most errors that occur during the LEARN REFERENCE procedure or the beginning of the AUTOCONVERGENCE pro- cedure are caused by one of the following:

Lens cap not removed

Lens focus not performed properly

Camera focus not performed properly

Ambient light is too high

Reference not learned properly

If all else fails, run the diagnostics.

To start up the EYE-QTMDiagnostics:

Highlight EYE-QTMby pushing up or down keys of the con- trol disc;

Press the <ENTER> button.

EYE-Q

 

 

TOUCH UP

 

 

AUTOCONVERGENCE

 

 

QUICK AUTOPICTURE

 

 

FULL AUTOPICTURE

 

 

EYE-Q SETUP

 

 

EYE-Q DIAGNOSTICS

 

 

EYE-Q

TM

 

DIAGNOSTICS

Interferance Test

PASS

Generic Test PASS

Sync Test

PASS

Ram Test

PASS

EYE-Q TM has been given

a clean bill of HEALTH.

After the <ENTER> button is pressed, the EYE-QTMDIAGNOS- TICS menu will be displayed and the Tests start instantly.

It includes check-ups on four items:

Interface Test;

Generic Test;

Sync Test;

Ram Test.

After completing each test, the status report will give the test result:

Pass; or

Failed plus the error number.

During the Interface Test, the following messages will displayed one after another on the screen:

Ready and Config Test;

Ready and Config OK;

Config Ackn. Test;

Config Ackn. OK;

Full Config Test;

Full Config OK;

Interface Test OK.

In case of failures, the error message will be shown:

FAILED... Error 01; or

FAILED... Error 02; or

FAILED... Error 03;.

During the Generic Test, the following messages will be displayed one after another on the screen:

Config for Generic;

Config for Generic OK;

Chipselects Test;

Chipselects OK;

Addressability Test;

10-15

Page 65
Image 65
Runco DTV-947 manual Eye-Q