EYE-QTMAutoconvergence

LEARNING A REFERENCE

Adjust one Reference Source with perfect geometry. This source can have either hori- zontal or vertical frequency. Remember that other sources will have the same geometry as this Reference Source. This means that if a source has 4:3 aspect ratio, all sources will be adjusted with a 4:3 aspect ratio and the same horizontal and vertical amplitudes.

Follow the steps below to select:

Enter in the Adjustment Mode and select EYE-QTMby pushing up or down keys of the control disc. Now select SETUP using the up or down keys, finally select

LEARN REFERENCE.

EYE-QTMwill now project the Reference Source with horizontal green line inserted at the top region and a horizontal green line inserted at the bottom region of the image.

Pushing the up or down keys of the control disc adjust the horizontal green line at the top until it matches the top edge of the Reference Source perfectly, then press <ENTER>.

Using the up or down keys of the control disc adjust the horizontal green line at the bottom until it matches the bottom edge of the Reference Source perfectly, then press <ENTER>.

Now EYE-QTMprojects the Reference Source with a vertical green line inserted at the left and a vertical green line inserted at the right.

Pushing the up or down keys of the control disc changes the position of the verti- cal green lines simultaneously; they are being shifted symmetrically inward and outward with respect to the scan of the projector.

Use left or right keys of the control disc to change the phase of the Reference Source. Use both (up or down) or (left or right) so that the green vertical lines perfectly match the right-left edges of the reference image, then press <ENTER> (this will initiate the learning procedure).

NOTE: If you had to use the left and right arrow keys to adjust the phase, this means that the phase of the Reference Source was originally not adjusted correctly. Hence the Reference Source may now fall short of the physical screen. To avoid this, re-adjust the Horizontal Raster Shift (in the Random Access Adjustment mode, refer to Owner Man- ual) so that the Reference source falls on the physical screen and repeat the Learn Ref- erence selection.

Do not adjust the phase when repeating the Learn Reference procedure.

Pressing<EXIT> will interrupt the Learn Reference procedure if required.

WHAT IS BEING MEASURED BY EYE-QTM

Using the borderlines define above, EYE-QTMknows exactly when the image starts and stops with respect to time scale. EYE-QTMis now able to project lines at the edges. Using the border lines left and right, EYE-QTMprojects three vertical thick green lines at posi- tions 5, 50 and 95%. Using the border lines top and bottom, EYE-QTMprojects three hor- izontal thick lines at positions 5, 50 and 95%. EYE-QTMthen calculates the intercepts of the three vertical and three horizontal lines resulting in nine points. These nine points are the reference points for other geometry sources and are stored into memory.

NOTE: “DELETE ALL BLOCKS” in the Service menu does not delete the Reference source parameters.

10-9

ADJUSTMENT MODE

Select a path from below:

EYE-Q

GUIDED

RANDOM ACCESS

EYE-Q

 

TOUCH UP

 

AUTOCONVERGENCE

 

QUICK AUTOPICTURE

 

FULL AUTOPICTURE

 

EYE-Q SETUP

 

EYE-Q DIAGNOSTICS

 

EYE-Q SETUP

FOCUS THE LENS

CENTER THE CAMERA

CONFIGURATION: rear/front

LEARN REFERENCE

TOUCH-UP OPTIONS:

Select with

or

then <ENTER>.

<EXIT> to return

Top Green Line

Top Edge

REFERENCE SOURCE

Bottom Green Line

Bottom Edge

Right Green Line

Right Edge

REFERENCE SOURCE

Left Edge

Left Green Line

Page 59
Image 59
Runco DTV-947 manual Learning a Reference, Learn Reference