Maintenance and Troubleshooting
76 Runco VX-40d/-50d/-60d/-80d Owner’s Operating Manual
PRELIMINARY
5.2
Lens Replacement
If you need to remove the lens – either to replace it or to prepare the projector for
shipment – proceed as follows:
1. Power down the projector and wait five minutes to allow the lamp to cool.
2. Remove the secondary anamorphic lens, if present.
3. Place the lens cap on the installed lens to protect it from damage.
4. Press and hold the “lens release” button located in the top right corn er of the lens
panel.
5. Grasping the lens barrel, turn it in a counter-clockwise direction until it stops . Then, pull
it forward to remove it (disconnects from the connector assembly).
Figure 5-6. Removing the Primary Lens
Note: The connector assembly moves as you turn the lens.
3
4
5