Maintenance and Troubleshooting
80 Runco VX-40d/-50d/-60d/-80d Owner’s Operating Manual
PRELIMINARY
Lamp Failures
20 Lamp turned on unexpectedly (fault related to ballast).
21 Lamp airflow low, overheating imminent.
23 Cannot read valid ballast ID.
26 Lamp 1 Interlock: lamp door open, lamp not installed.
27 Can’t turn lamp on.
28 Lamp turned off unexpectedly.
29 Lamp ballast overheated.
Power and Cooling
46 Red DMD heat sink overheated.
47 Green DMD heat sink overheated.
48 Blue DMD heat sink overheated.
49 Prism overheated.
4C Projector shutdown due to critical error.
C0 Lamp blower failure (lamp not turned on).
51 LVPS fan failed (Fan 1).
52 LVPS/Red cooling fan failed (Fan 2).
53 DC lamp fan failed (VX-40d or VX-60d; Fan 3).
54 Red DMD heatsink fan failed (Fan 4).
55 Green DMD heatsink fan failed (Fan 5).
56 Blue DMD heatsink fan failed (Fan 6).
57 TIPM fan failed (Fan 7).
58 TIPM fan failed (Fan 8).
Table 5-2. VX-40d/-50d/-60d/-80d Error Codes (continued)
Code Description
Note: To clear a system error, press the EXIT key (on the projector’s rear-panel keypad) twice. If
necessary, reset the projector by powering it off, allowing it to cool and powering it on again.
Contact your Runco dealer or Runco technical support if the error persists.