Maintenance and Troubleshooting
Table 5-2. VX-40d/-50d/-60d/-80d Error Codes (continued)
Code | Description |
|
|
| Lamp Failures |
|
|
20 | Lamp turned on unexpectedly (fault related to ballast). |
|
|
21 | Lamp airflow low, overheating imminent. |
|
|
23 | Cannot read valid ballast ID. |
|
|
26 | Lamp 1 Interlock: lamp door open, lamp not installed. |
|
|
27 | Can’t turn lamp on. |
|
|
28 | Lamp turned off unexpectedly. |
|
|
29 | Lamp ballast overheated. |
|
|
| Power and Cooling |
|
|
46 | Red DMD heat sink overheated. |
|
|
47 | Green DMD heat sink overheated. |
|
|
48 | Blue DMD heat sink overheated. |
|
|
49 | Prism overheated. |
|
|
4C | Projector shutdown due to critical error. |
|
|
C0 | Lamp blower failure (lamp not turned on). |
|
|
51 | LVPS fan failed (Fan 1). |
|
|
52 | LVPS/Red cooling fan failed (Fan 2). |
|
|
53 | DC lamp fan failed |
|
|
54 | Red DMD heatsink fan failed (Fan 4). |
|
|
55 | Green DMD heatsink fan failed (Fan 5). |
|
|
56 | Blue DMD heatsink fan failed (Fan 6). |
|
|
57 | TIPM fan failed (Fan 7). |
|
|
58 | TIPM fan failed (Fan 8). |
|
|
Note: To clear a system error, press the EXIT key (on the projector’s
80 | Runco |