3-26. Duct for Fresh Air
There is a duct connection port
3-27. Shaping the Tubing
●The positions of the refrigerant tubing connections are shown in the figure below. (The tubing can be routed in 3 directions.)
*When routing the tubing out through the top or right sides, knock out the appropriate parts in the top panel and cut notches in the side panel as shown in Fig.
*When routing the tubing out through the top, the optional
Rear outlet port
Outside air intake duct connection port
Power supply outlet
Rear tubing hole
Fig.
If the tubing is to be routed out together, use a box cutter or simi- lar tool to cut out the part of the rear cover indicated by the marked area in the figure below, to match the positions of the tubes. Then draw out the tubing.
T
Rear cover
Fig. 3-105
●Prepare standard PVC pipe for the drain and connect it to the indoor unit drain pipe with the supplied hose clamps to prevent water leaks.
(1) Drain hose connection
●The drain hose is connected below the refrigerant tubing.
(2) Installing the drain hose
●To install the drain hose, first place 1 of the 2 hose bands over the unit drain port and the other hose band over the hard PVC pipe (not supplied). Then connect both ends of the supplied drain hose.
●On the unit drain side, grasp the hose band with pliers and insert the drain hose all the way to the base.
●If other commercially available hose bands are used, the drain hose may become pinched or wrinkled and there is danger of water leakage. Therefore be sure to use the supplied hose bands. When sliding the hose bands, be careful to avoid scratching the drain hose.
●Do not use adhesive when connecting the supplied drain hose to the drain port (either on the main unit or the PVC pipe).
●Wrap the hose with the supplied drain hose insulation and use the 4 twist ties so that the hose is insulated with no gaps.
●Connect the drain piping so that it slopes downward from the unit to the outside. (Fig.
Fig.
Donward gradient
Min. 1/100
Good
Not good
Fig.
CAUTION
●Attach so that the hose band fastener is on the side of the drain port. (Fig.
●Attach the hose bands so that each is approximately 13/64 – 63/64 in. from the end of the supplied drain hose.
50