Indoor Unit

KHS3682

Control PCB

Part No.

Controls

Control Circuit Fuse

Remote Control Unit

Fan

CB-KHS3682

Microprocessor

250V 3A

RCS-8HVPULS4U

Type

 

Q'ty ... Dia. and Length

inch (mm)

Cross-Flow

1 ... D3-15/16 / L32-1 (D100/L838)

Fan Motor

 

 

 

Type

 

DC Motor

 

Model ... Q'ty

 

SIC-39CVL-D847-10 ... 1

 

No. of Poles

 

8

 

Rough Measure RPM (Cool / Heat)

 

1,370 / 1,450

 

Nominal Output

W

47

 

Coil Resistance

Ohm

-

 

(Ambient Temp. 68 °F (20 °C))

 

 

 

Safety Device

 

 

 

 

Type

 

Internal Controller

 

 

Over-Current Protection

 

Yes

 

 

Over-Heat Protection

 

Yes

 

Run Capacitor

Micro F

-

 

 

 

VAC

-

 

 

 

 

 

Flap Motor

 

 

 

Type

 

Stepping Motor

 

Model

 

24BYJ48-1256

 

Rating

 

DC 12V

 

Coil Resistance

Ohm

Each Pair of Terminal : 200 +/- 7%

 

(Ambient Temp. 77 °F (25 °C))

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

Coil

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

1 and 2

 

Fins Per inch

 

19.5

 

Face Area

ft2 (m2)

4.55 (0.423)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

12

Page 12
Image 12
Sanyo KHS3682 + CH3682, KHS3082 + CH3082 service manual CB-KHS3682 Microprocessor 250V 3A