Indoor Unit

: KHS3682

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CH3682

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Heating Capacity >

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

36,000 BTU/h

 

AIR FLOW RATE:

 

671 CFM

 

 

OUTDOOR

 

 

 

 

 

INDOOR

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

 

W.B.

 

 

 

60

65

 

70

75

 

80

 

 

 

 

 

 

 

(15.6)

(18.3)

 

(21.1)

(23.9)

 

(26.7)

 

 

0

(-17.8)

 

TH

 

19,760

19,860

 

19,940

20,010

 

20,080

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

(-16.1)

 

TH

 

20,420

20,510

 

20,600

20,670

 

20,740

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

(-13.3)

 

TH

 

21,990

22,090

 

22,180

22,260

 

22,330

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

(-10.6)

 

TH

 

23,630

23,730

 

23,830

23,920

 

23,990

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

(-7.8)

 

TH

 

25,440

25,560

 

25,660

25,750

 

25,820

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

(-5.0)

 

TH

 

27,360

27,480

 

27,590

27,680

 

27,140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

(-2.2)

 

TH

 

29,370

29,490

 

29,600

29,700

 

27,580

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

(0.6)

 

TH

 

31,460

31,590

 

31,700

31,560

 

27,940

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

(3.3)

 

TH

 

33,540

33,670

 

33,780

31,900

 

28,210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

(6.1)

 

TH

 

35,760

35,890

 

#

36,000

32,150

 

28,410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

(8.9)

 

TH

 

38,030

38,160

 

36,450

32,300

 

28,520

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53

(11.7)

 

TH

 

40,340

40,460

 

36,500

32,330

 

28,530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

(14.4)

 

TH

 

42,580

41,040

 

36,420

32,230

 

28,430

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

(17.2)

 

TH

 

44,920

40,770

 

36,160

32,000

 

28,210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

(18.3)

 

TH

 

45,520

40,610

 

36,020

31,870

 

28,090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH : Total Heating Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

:Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

28

Page 28
Image 28
Sanyo KHS3682 + CH3682, KHS3082 + CH3082 service manual 36,000 BTU/h