3-7. Wire Size and Length

Regulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to your local elec- trical codes. Carefully observe these regulations when carrying out the installation.

NOTE

Refer to the wiring system diagram (Fig. 23) for the meaning of (A), (B), and (C) in Table 5.

Refer to your local codes or in the absence of local codes see the National Electric Code: ANSI/NFPA70.

Table 5

Model

 

(A) POWER SUPPLY WIRING

(B) POWER LINE

(C) CONTROL LINE

 

 

 

 

 

 

Wire Size

AWG12 (min.) or bigger (*1) for CH3082

AWG14 or bigger

AWG14 or bigger

 

AWG10 (min.) or bigger (*1) for CH3682

 

 

 

 

CH3082

 

 

 

 

Length

It depends on wire specification and

180 ft. (max.)

180 ft. (max.)

CH3682

supply voltage level (*2)

 

 

 

 

 

 

 

 

 

Fuse or Circuit

35A for CH3082

Disconnect switch

-

 

Breaker Capacity

45A for CH3682

(15A)

 

 

 

 

 

 

 

(AWG: American Wire Gauge)

(*1) It depends on supply voltage level and wire specification. Consider temperature rating of wire, ambient temperature, and the number of wires inside the conduit.

(*2) Requirement of supply voltage level: AC187V to 253V (Measure voltage level at terminal plate inside the outdoor unit.)

WARNING

Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).

Each wire must be firmly connected.

No wire should be allowed to touch refrigerant tubing, the compressor, or any moving part.

WARNING

To avoid the risk of electric shock, each air conditioner unit must be grounded.

For the installation of a grounding device, please observe local electrical codes.

Grounding is necessary, especially for units using inverter circuits, in order to release charged electricity and electrical noise caused by high tension. Otherwise, electrical shock may occur.

Place a dedicated ground more than 7' (2 m) away from other grounds and do not have it shared with other elec- tric appliances.

CAUTION

WIRING SYSTEM DIAGRAM

INDOOR

*Disconnect

 

OUTDOOR

 

60Hz

 

 

230/208V

UNIT

switch

 

UNIT

 

Terminal

Field supply

(B)

Terminal

 

 

 

 

 

1

 

 

1

 

 

 

 

supply phase

2

 

 

2

 

 

 

 

Power Single

3

 

 

3

(A)

 

(C)

 

 

 

 

 

 

 

 

4

 

L1

 

 

 

 

 

Grounding line

 

5

 

L2

 

 

 

 

 

 

(B)

 

 

 

 

 

 

 

Grounding

 

 

 

 

line

 

Fig. 23

*NOTE

Disconnect switch may be required by national or local codes.

CAUTION

Always comply with national and local code requirements.

Be sure to connect the power supply line to the outdoor unit as shown in the wiring diagram. The indoor unit draws its power from the outdoor unit.