5-3. Heating Capacity

Indoor Unit

: KHS3082

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

: CH3082

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Heating Capacity >

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

33,000 BTU/h

 

AIR FLOW RATE:

 

671 CFM

 

 

OUTDOOR

 

 

 

 

 

INDOOR

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

 

W.B.

 

 

 

60

65

 

70

75

 

80

 

 

 

 

 

 

 

(15.6)

(18.3)

 

(21.1)

(23.9)

 

(26.7)

 

 

0

(-17.8)

 

TH

 

18,060

18,120

 

18,170

18,210

 

18,240

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

(-16.1)

 

TH

 

18,670

18,730

 

18,780

18,820

 

18,850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

(-13.3)

 

TH

 

20,120

20,190

 

20,240

20,280

 

20,320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

(-10.6)

 

TH

 

21,640

21,710

 

21,770

21,810

 

21,840

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

(-7.8)

 

TH

 

23,320

23,390

 

23,450

23,500

 

23,530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

(-5.0)

 

TH

 

25,100

25,170

 

25,230

25,280

 

25,310

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

(-2.2)

 

TH

 

26,960

27,030

 

27,090

27,140

 

27,160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

(0.6)

 

TH

 

28,900

28,970

 

29,030

29,070

 

29,090

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

(3.3)

 

TH

 

30,830

30,900

 

30,950

30,990

 

30,500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

(6.1)

 

TH

 

32,880

32,950

 

#

33,000

33,030

 

30,830

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

(8.9)

 

TH

 

34,980

35,050

 

35,090

35,120

 

31,060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53

(11.7)

 

TH

 

37,120

37,180

 

37,220

35,460

 

31,180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

(14.4)

 

TH

 

39,210

39,260

 

39,280

35,480

 

31,180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

(17.2)

 

TH

 

41,380

41,410

 

40,090

35,340

 

31,050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

(18.3)

 

TH

 

42,230

42,260

 

39,980

35,250

 

30,960

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH : Total Heating Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.

:Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.

2.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

27

Page 27
Image 27
Sanyo KHS3082 + CH3082, CH3682 Power Supply 230V Single Phase 60Hz Heating Capacity, TH Total Heating Capacity BTU/h