(3-2) Alarm Code : E07/P04/P05/P20/P27
Troubleshooting Serial Communication
1.Turn off the power and wait until the power lamp (LED) of the outdoor unit controller is turned OFF.
2.Disconnect the cable from the terminal 3 on the Outdoor
unit terminal strip.(Fig. 6)
1.Turn ON the power and operate the system using the remote controller or the operation button on the indoor unit.
2.Perform the
Outdoor Unit
1 2 3 4 5 6
Power
1 2 3
Indoor Unit
Fig. 6
Alarm Code : E05
What is the latest
Alarm Code : E07/P04/P05/
P20/P27
1.Turn off the power and wait until the power lamp (LED) of the outdoor unit controller is turned OFF.
2.Disconnect the cable from the terminal 3 on the indoor
unit terminal strip.(Fig. 7)
1.Turn ON the power and operate the system using the remote controller or the operation button on the indoor unit.
2.Perform the
Alarm Code : E05
What is the latest
Alarm Code : E07/P04/P05/
P20/P27
Defect in the indoor unit
P.C. board
Outdoor Unit
1 2 3 4 5 6
Power 1 2 3
Indoor Unit
Fig. 7
Defect in the
cable
47