Sanyo KHS3082 + CH3082 To unmount indoor unit, Frame Fastening Method, Do not supply power to

Models: KHS3082 + CH3082 CH3682 CH3082 KHS3682 + CH3682

1 109
Download 109 pages 19.55 Kb
Page 99
Image 99

To unmount indoor unit

Press the 2 marks on the lower part of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount. (Fig. 42)

3-10. Frame Fastening Method

(1)Remove the screw cover on the bottom surface. (Fig. 43)

(2)Fasten the frame to the rear panel using the 2 sup- plied tapping screws 5/32" x 13/32" (4 x 10 mm). (Fig. 43)

NOTE

Under normal conditions, the installation design calls for a less than 3/32" (2 mm) gap between the air conditioner unit and the wall.

Confirm that the gap is appropriate (less than 2 mm).

3-11. Drain Hose

a)The drain hose should be slanted downward to the outdoors. (Fig. 44)

b)Never form a trap in the course of the hose.

c)If the drain hose will run in the room, insulate the hose with insulation* so that chilled condensation will not damage furniture or floors. (Fig. 45)

* Foamed polyethylene or its equivalent is recom- mended.

WARNING

Do not supply power to the

 

unit or operate it until all

 

tubing and wiring to the out-

 

side unit are completed.

Risk of Electric Shock

Push

Fig. 42

Screw cover

Screw

Fig. 43

 

Slant

Indoor

Drain

unit

hose

 

Fig. 44

Condensation

Insulation material (Locally purchased) must be used.

Fig. 45

21

Page 99
Image 99
Sanyo KHS3082 + CH3082 To unmount indoor unit, Frame Fastening Method, Do not supply power to, Side unit are completed